Compact-Y NF Plus
THAETY 115-127 NF
Cooling capacity: 15.5÷26.6 kW
Heating capacity: 16.6÷30.4 kW
WEBCODE: CYP01
Product benefits
- Hot water up to –15°C outdoor air
- Temperature of the produced water up to 60°C
- Plug&Play unit with integrated hydraulic module
- Included evaporating/condensing control


Packaged reversible air-cooled heat pumps with axial fans. Range with hermetic scroll compressors and R410A refrigerant gas.
Construction features
• Compressor: hermetic, rotary scroll compressor, complete with thermal protection and casing heater for mod. 127.
• Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins with hydrophilic treatment and complete with protection grille.
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed regulation.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate, complete with condensate drain pan and unit base antifreeze heater.
Version
• T - High efficiency/temperature version.
Models
• THAETY: heat pump unit.
PUMP set up
• Pump unit complete with: circulator or electric circulation pump, membrane expansion tank, manual air vent valve, safety valve and pressure gauge.
TANK&PUMP set up
• Pump unit complete with: inertial buffer tank, circulator or electric circulation pump, membrane expansion tank, manual air vent valve, automatic air vent valve, safety valve, and pressure gauge.
Factory fitted accessories
• Soft-start device.
• Silenced set up.
• Antifreeze heater on the tank.
• Compressor casing heater (mod. 115÷124).
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Low water set-point temperature.
Separately supplied accessories
• 3-way valve for the production of domestic hot water, managed by regulation.
• Additional electrical resistance for heat pump, managed by regulation.
• Outdoor air temperature probe for set-point compensation.
• Rubber anti-vibration mounts.
• Water filter.
• Remote keypad with display.
• Clock board.
• Interfaces for serial communication with other devices.
• Serial converter (RS485/USB).
• Rhoss supervisors for unit monitoring and remote management.
THAETY NF MODEL | ||
❶ | Heating capacity | kW |
❶ | Absorbed power | kW |
❶ | C.O.P. | |
❷ | Heating capacity | kW |
❷ | Absorbed power | kW |
❷ | C.O.P. | |
❸ | Heating capacity | kW |
❸ | C.O.P. | |
❹ | Cooling capacity | kW |
❹ | Absorbed power | kW |
❹ | E.E.R. | |
❺ | Sound pressure | dB(A) |
❺ | Silenced set up sound pressure | dB(A) |
Scroll/step compressor | no. | |
Buffer tank water content | l | |
❹ | P0 circulator/P1 electric pump nominal available head | kPa |
Electrical supply | V-ph-Hz | |
DIMENSIONS AND WEIGHTS | ||
L - PUMP width | mm | |
L - TANK&PUMP width | mm | |
H - Height | mm | |
P - Depth | mm | |
❻ | Weight | kg |
SEASONAL ENERGY PERFORMANCE | ||
THAETY NF MODEL SEASONAL PERFORMANCE IN HEATING MODE | ||
③ | Pdesignh (EN 14825) | kW |
③ | SCOP (EN 14825) | |
④ | ηs | % |
④ | Energy class | |
115 | 117 | 122 | 124 | 127 |
16,6 | 17,7 | 23,4 | 25,9 | 30,4 |
5,72 | 6,32 | 8,18 | 9,08 | 10,03 |
2,9 | 2,8 | 2,86 | 2,85 | 3,03 |
18 | 19 | 24,8 | 27,8 | 32,3 |
4,33 | 4,53 | 5,9 | 6,59 | 7,58 |
4,16 | 4,19 | 4,2 | 4,22 | 4,26 |
11,7 | 12 | 15,7 | 17,9 | 20,8 |
2,77 | 2,77 | 2,8 | 2,77 | 2,84 |
15,5 | 17,6 | 22,5 | 23,9 | 26,6 |
5,81 | 6,62 | 8,14 | 9,45 | 10,11 |
2,67 | 2,66 | 2,75 | 2,53 | 2,63 |
50 | 50 | 52 | 52 | 53 |
46 | 46 | 49 | 49 | 50 |
1/1 | 1/1 | 1/1 | 1/1 | 1/1 |
35 | 35 | 45 | 45 | 45 |
75/147 | 64/136 | 66/131 | 69/130 | 63/116 |
400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 |
115 | 117 | 122 | 124 | 127 |
1230 | 1230 | 1230 | 1230 | 1535 |
1522 | 1522 | 1522 | 1522 | 1822 |
1090 | 1090 | 1280 | 1280 | 1510 |
580 | 580 | 600 | 600 | 695 |
215 | 225 | 278 | 288 | 320 |
115 | 117 | 122 | 124 | 127 |
18 | 18 | 24 | 27 | 32 |
3,62 | 3,74 | 3,72 | 3,74 | 3,68 |
142 | 146 | 146 | 146 | 144 |
A+ | A+ | A+ | A+ | A+ |
Data at the following conditions: |
|
❶ |
Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C. |
❷ |
Air: 7°C D.B. - 6°C W.B. - Water: 30/35°C. |
❸ |
Air: -7°C D.B. - Water: 30/35°C. |
❹ |
Air: 35° D.B. - Water: 12/7°C. |
❺ |
In open field (Q = 2) at 5 m from the unit. |
❻ |
Weight refers to most complete set up. |
Performance according to EN 14511:2018. Set up with circulator. |
|
Important note: |
|
- With circulator (P0/ASP0 set up) the units are not suitable for radiant cooling operation. |
|
- Permissible heat exchanger thermal gradient ΔT = 4÷8°C. |
|
③ |
In Average climatic conditions, low temperature application (35°C) |
④ |
Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013) |