Fan coils with EC motor
YARDY-I EV3
Cooling capacity: 1.9÷8.4 kW
Heating capacity: 2.5÷11.8 kW
WEBCODE: YARI3 ACMEC controls: ACREG
Product benefits
- New white RAL 9003 for versions with cabinet
- New touch controls
- Air'Suite biocide filter for healthier and cleaner air in indoor environments
- Enhanced performance with 4-row coil
- Consumption reduced by 50% with EC motor
- Continuous fan speed regulation













Floor and ceiling fan coil units with cabinet for recessed wall or false ceiling installation
Construction features
• Heat exchanger: with finned coil with left side connections reversible to the right.
• Centrifugal fan with an inverter controlled electronic brushless motor and continuous speed adjustment.
• Cabinet version structure: covering cabinet in pre-painted sheet steel, RAL9003, complete with a regenerable filter, ABS polymer grilles and a natural condensate drain pan.
• Recessed version structure: in galvanised sheet steel, complete with a natural condensate drain pan and regenerable filter.
Versions
• MVP - Vertical unit with cabinet equipped with lower air inlet and upper delivery for wall mounting installation or with feet on the ground.
• MVT - Vertical unit with cabinet equipped with front air inlet and upper delivery for floor installation.
• MXP - Horizontal/vertical unit with cabinet, equipped with lower air inlet and upper delivery, for ceiling installation, wall mounted or with feet on the ground.
• MXT - Horizontal/vertical unit with cabinet, equipped with front air inlet and upper delivery, for ceiling or floor installation.
• IVP - Recessed vertical unit equipped with lower air inlet and upper delivery for wall mounting installation.
• IVF - Recessed vertical unit equipped with lower air inlet and front delivery for wall mounting installation.
• IXP - Horizontal/vertical unit equipped with lower air inlet and upper delivery for false ceiling or recessed wall installation.
Construction set-ups
Type of unit
2T - Single main coil.
4T - Double main coil and additional.
ACCESSORIES
➔❖ Additional water heating coil for 4-pipe systems.
➔❖ Electrical resistance.
➔❖ 2 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 3 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 4-way ON/OFF electrovalves for 4-pipe systems with single main coil.
➔❖ Auxiliary condensate drain pan.
➔❖ Air'Suite biocide filter.
❖ Electrical box for connection terminal block.
❖ Air inlet flange: Ø10cm or Ø12cm.
➔ Manual damper.
➔ Motorised damper.
➔ Back in view.
➔ Rear closing panel.
➔ Rear closing panel with grille and filter.
➔ Support feet with pipe cover.
➔ Flanged frame for duct connection.
➔ Frame with Air'Suite biocide filter (G2) that can be extracted in any direction.
➔ Delivery straight fitting.
➔ 90° delivery and inlet fitting.
➔ Telescopic outlet/inlet fitting.
➔ Inlet grille with filter.
➔ Delivery grille.
➔ Formwork for recessed wall or false ceiling installation.
➔ Aesthetic panel for wall mounted formwork, with air delivery and return grille.
➔ Aesthetic panel for formwork, with air inlet grille.
➔ Delivery nozzle made of aluminium, with a double row of adjustable fins.
➔ Anti-vibration fitting for delivery/inlet duct connection.
➔ Intake/outlet plenum with round nozzles.
CONTROLS
STANDARD controls
For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.
Advanced LIT-TOUCH controls
➔ Flush LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ Wall mounted LIT-Touch remote control and receiver with air temperature probe and operation LED.
➔❖ LIT-Touch control with air temperature probe for on board installation.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with a minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔❖ Additional board with 2 digital outputs that can be configured.
➔❖ On board air temperature probe.
➔❖ RS485 serial board for serial communication with other devices (Modbus RTU protocol).
Key: ❖ Factory fitted
➔ Supplied separately
YARDY-I EV3 MVP-MVT-MXP-MXT-IVP-IVF-IXP | ||
❶ | Total cooling capacity [EN1397] | kW |
kW | ||
kW | ||
❷ | Heating capacity (45°C) [EN1397] | kW |
kW | ||
kW | ||
❸ | Heating capacity (50°C) | kW |
kW | ||
kW | ||
❹ | Heating capacity (70°C) [EN1397] | kW |
kW | ||
kW | ||
❺ | Heating capacity of additional coil (65°C) [EN1397] | kW |
kW | ||
kW | ||
❹ | Heating capacity of additional coil (70°C) [EN1397] | kW |
kW | ||
kW | ||
Air flow speed | m³/h | |
m³/h | ||
m³/h | ||
Sound power | dB(A) | |
dB(A) | ||
dB(A) | ||
❻ | Sound pressure | dB(A) |
dB(A) | ||
dB(A) | ||
Absorbed power | W | |
W | ||
W | ||
Electrical supply | V-ph-Hz | |
DIMENSIONS AND WEIGHTS | ||
L - MXP-MXT-MVP-MVT width | mm | |
L - IVP-IXP-IVF width | mm | |
H - MXP-MXT-MVP-MVT height | mm | |
H - IVP-IXP-IVF height | mm | |
MVP-MVT-MXP-MXT Feet height | mm | |
P - MXP-MXT-MVP-MVT Depth | mm | |
P - IVP-IXP-IVF Depth | mm | |
MXP-MXT-MVP-MVT Weight | kg | |
IVP-IXP-IVF Weight | kg | |
20 | 24 | 30 | 34 | 45 | 48 | 60 | 74 | 80 | 88 |
1,86 | 2,24 | 2,97 | 3,37 | 4,11 | 4,6 | 6,28 | 7,33 | 7,94 | 8,4 |
1,44 | 1,68 | 2,33 | 2,75 | 3,05 | 3,49 | 4,6 | 5,24 | 5,87 | 6,32 |
0,75 | 0,8 | 1,08 | 1,34 | 1,53 | 1,73 | 1,78 | 2,1 | 2,1 | 2,25 |
2,1 | 2,18 | 3,27 | 3,41 | 4,47 | 4,65 | 7,13 | 7,41 | 9,67 | 10,07 |
1,48 | 1,57 | 2,52 | 2,6 | 3,13 | 3,27 | 5,12 | 5,31 | 7,15 | 7,43 |
0,77 | 0,81 | 1,2 | 1,26 | 1,5 | 1,57 | 1,88 | 1,94 | 2,63 | 2,74 |
2,47 | 2,6 | 3,87 | 4,07 | 5,3 | 5,54 | 8,38 | 8,81 | 11,29 | 11,77 |
1,77 | 1,88 | 2,99 | 3,14 | 3,74 | 3,93 | 6,07 | 6,37 | 8,39 | 8,75 |
0,92 | 0,97 | 1,42 | 1,52 | 1,81 | 1,9 | 2,25 | 2,36 | 3,07 | 3,22 |
4,2 | 4,36 | 6,56 | 6,85 | 8,96 | 9,31 | 14,28 | 14,86 | 19,35 | 20,14 |
2,98 | 3,14 | 5,06 | 5,26 | 6,28 | 6,56 | 10,3 | 10,77 | 14,35 | 14,91 |
1,56 | 1,64 | 2,44 | 2,56 | 3,06 | 3,19 | 3,87 | 3,98 | 5,37 | 5,6 |
1,95 | 2,08 | 2,94 | 2,8 | 3,36 | 3,2 | 5,64 | 5,37 | 6,5 | 6,17 |
1,66 | 1,6 | 2,34 | 2,22 | 2,84 | 2,7 | 4,67 | 4,45 | 5,39 | 5,14 |
0,87 | 0,83 | 1,3 | 1,23 | 1,53 | 1,46 | 2,17 | 2,06 | 2,51 | 2,4 |
2,21 | 2,36 | 3,33 | 3,17 | 3,83 | 3,64 | 6,38 | 6,08 | 7,37 | 6,98 |
1,92 | 1,84 | 2,65 | 2,52 | 3,3 | 3,15 | 5,3 | 5,04 | 6,12 | 5,83 |
1,01 | 0,96 | 1,48 | 1,41 | 1,79 | 1,7 | 2,5 | 2,38 | 2,9 | 2,76 |
331 | 331 | 523 | 523 | 645 | 645 | 1235 | 1235 | 1503 | 1458 |
230 | 230 | 400 | 400 | 450 | 450 | 780 | 780 | 965 | 965 |
97 | 97 | 167 | 167 | 198 | 198 | 256 | 256 | 300 | 300 |
48 | 48 | 50 | 50 | 51 | 51 | 62 | 62 | 66 | 66 |
40 | 40 | 43 | 43 | 42 | 42 | 50 | 50 | 56 | 56 |
29 | 29 | 29 | 29 | 29 | 29 | 30 | 30 | 32 | 32 |
39 | 39 | 41 | 41 | 42 | 42 | 53 | 53 | 57 | 57 |
31 | 31 | 34 | 34 | 33 | 33 | 41 | 41 | 47 | 47 |
20 | 20 | 20 | 20 | 20 | 20 | 21 | 21 | 23 | 23 |
23 | 25 | 26 | 28 | 39 | 42 | 89 | 95 | 136 | 146 |
13 | 14 | 15 | 16 | 14 | 15 | 28 | 30 | 52 | 56 |
6 | 6 | 6 | 6 | 7 | 8 | 7 | 7 | 9 | 10 |
230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 |
20 | 24 | 30 | 34 | 45 | 48 | 60 | 74 | 80 | 88 |
800 | 800 | 1000 | 1000 | 1200 | 1200 | 1500 | 1500 | 1500 | 1500 |
550 | 550 | 750 | 750 | 950 | 950 | 1250 | 1250 | 1250 | 1250 |
570 | 570 | 570 | 570 | 570 | 570 | 570 | 570 | 570 | 570 |
545 | 545 | 545 | 545 | 545 | 545 | 545 | 545 | 545 | 545 |
100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 |
212 | 212 | 212 | 212 | 212 | 212 | 212 | 212 | 212 | 212 |
20 | 20,5 | 21 | 22 | 28 | 29 | 35 | 36 | 37 | 38 |
16,5 | 17 | 20,5 | 21,5 | 25,5 | 27 | 34,5 | 35,5 | 36,5 | 37,5 |
Data at the following conditions: |
|
❶ |
Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. |
❷ |
Air: 20°C - Water: 45/40°C. |
❸ |
Air: 20°C - Water: 50°C, flow rate as in cooling. |
❹ |
Air: 20°C - Water: 70/60°C. |
❺ |
Air: 20°C - Water: 65/55°C. |
❻ |
For room volume equal to 100 m³ and reverberation time = 0.5 sec. |
E |
Eurovent certified performance. |
Performance refers to the motor’s input signal: 10V - 6V - 1V at MAX - MED - MIN speed. |
|
YARDY-I EV3 24 - 34 - 48 - 74 - 88 with oversized 4-row coil. |
|
For the selection with Air'Suite filter, refer to the UP-TO-DATE selection Software. |
|
For the selection with Air'Suite filter, refer to the UP-TO-DATE selection Software. |